Model
|
S-100-5
|
S-100-12
|
S-100-15
|
S-100-24
|
S-100-48
|
DC output voltage
|
5V
|
12V
|
15V
|
24V
|
48V
|
DC output current
|
20A
|
8.5A
|
6.7A
|
4.5A
|
2A
|
Wave and noise
|
100mVp-p
|
120mVp-p
|
120mVp-p
|
150mVp-p
|
150mVp-p
|
Inlet stability
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load stablity
|
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Efficiency
|
78%
|
80%
|
80%
|
82%
|
83%
|
Adjustable range for DC voltage
|
±10%
|
±10%
|
±10%
|
±10%
|
±10%
|
AC input voltage range
|
90~132VAC 180~264VAC 47~63Hz 255~373VDC
|
AC Impact current
|
Cold-start current 30A/230V
|
Overload proctection
|
115%-150% cut off the output, restart
|
Setup rise hold up time
|
200ms, 50ms, 20ms/230VAC at full load
|
|
|
|
|
Withstand voltage
|
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
|
Isolation resistance
|
Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ
|
Working temperature and humidity
|
-10°C~+60°C(Refer to output derating curve),20%~90%RH
|
Overall dimension
|
199*98*38mm
|
Weight
|
0.63Kg
|
Note:
|
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity.
|
2.Error.include the setting error,line stability and load stability.(Note:5).
|
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
|
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
|
5.Load stability test:the load is from 0% to 100%.
|
6.C2,3,6must be knocked down.
|