Yueqing zhijiu electric Co., Ltd

Products >> switching power supply-samll power >> 50W

  • 50W Single output switching power supply
  • 50W Single output switching power supply
  • 50W Single output switching power supply
  • 50W Single output switching power supply
50W Single output switching power supply 50W Single output switching power supply 50W Single output switching power supply 50W Single output switching power supply

50W Single output switching power supply

 
Model
S-50-5
S-50-12
S-50-15
S-50-24
DC output voltage
5V
12V
15V
24V
DC output current
10A
4.2A
3.4A
2.1A
Wave and noise
100mVp-p
120mVp-p
120mVp-p
120mVp-p
Inlet stability
±0.5%
±0.5%
±0.5%
±0.5%
Load stablity
±1%
±0.5%
±0.5%
±0.5%
Efficiency
76%
79%
79%
82%
Adjustable range for DC voltage
±10%
±10%
±10%
±10%
AC input voltage range
90~132VAC 180~264VAC 47~63Hz 255~373VDC
AC Impact current
Cold-start current 30A/230V
Overload proctection
115~150% fold back current limiting, automatic recovery
Setup rise hold up time
200ms, 50ms, 20ms/230VAC at full load
Withstand voltage
Input and output internal:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC
Isolation resistance
Input and output internal:Input and enclosure,Output and enclosure:500VDC/100MΩ
Working temperature and humidity
-10°C~+60°C(Refer to output derating curve),20%~90%RH
Overall dimension
159*97*38mm
Weight
0.51Kg
Note:
1.The testing condition for the paramenter above is :230VAC input,rated load,25°C70% RH.Humidity.
2.Error.include the setting error,line stability and load stability.(Note:5).
3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage.
5.Load stability test:the load is from 0% to 100%.
6.C2,3,6must be knocked down.

Contact Us

WechatClose
Wechat